multi-channel vibration measurement data logging recording
multi-channel lithium-ion battery r&d testing data recording
portable remote climate monitoring
portable  multi channel temperature humidity data acquisition loggers

GL7000
Multi-Channel Datalogger Sampling Rates

multichannel modular standalone datalogger


ITEM

Channels
Per Unit

Max Sampling Rate

Storage Options

Multiple Unit Maximum Sampling Speed
Using 1-2 Units | Using 3-4 Units | Using 5-10 Units

Voltage Unit
GL7-V

10ch 100S/s
(10ms)
RAM 1kS/s (1ms)
Internal Flash Memory
SD Card
SSD (*2)

Voltage
Temp
GL7-M

10ch 1kS/s
(1ms)
RAM 100kS/s (10ms)
Internal Flash Memory
SD Card
SSD (*2)

High Speed
Voltage Unit
GL7-HSV

4ch 1MS/s
(1μs)
RAM 1MS/s (1μs)
Internal Flash Memory   1kS/s (1ms)  
SD Card
SSD (*2) 1MS/s (1μs) 500 kS/s (2μs) 200 kS/s (5μs)

High Voltage
GL7-HV

2ch 1MS/s
(1μs)
RAM 1MS/s (1μs)
Internal Flash Memory   1kS/s (1ms)  
SD Card
SSD (*2) 1MS/s (1μs) 500 kS/s (2μs) 200 kS/s (5μs)

Strain Unit
GL7-DCB

4ch 100kS/s
(10μs)
RAM 10kS/s (10μs) (*1)
Internal Flash Memory 1kS/s (1ms) (*1)
SD Card
SSD (*2) 100 kS/s (10μs) (*1)

Acceleration Unit
GL7-CHA

4ch 100kS/s
(10μs)
RAM 100kS/s (10μs) (*1)
Internal Flash Memory 1kS/s (1ms)
SD Card
SSD (*2) 100kS/s (10μs) (*1)

Logic/Pulse Unit
GL7-L/P

16ch Logic
1MS/s
(1μs)
RAM 10MS/s (*1)
Internal Flash Memory 1kS/s (*1)
SD Card
SSD (*2) 1MS/s (1μs) 500 kS/s (2μs) 200 kS/s (5μs) (*1)
Pulse
10kS/s
(100μs)
RAM 10kS/s (100μs)
1kS/s (1ms)
Cannot Measure (*1)
Internal Flash Memory
SD Card
SSD (*2) 10kS/s (100μs)  

ITEM

Channels
Per Unit

Maximum Output Sampling

Multiple Unit Maximum Sampling Speed
Using 1-2 Units | Using 3-4 Units | Using 5-10 Units

Analog Voltage Output
GL7-DCO

8ch 10kS/s
(10μs)
As an output unit, there are no recording settings on the GL7-DCO. (Data from other amp units is receivable while executing analog voltage (*3) output.)

 

(*1) There are limits to adding additional amplifier units. (Logic units: 7, Pulse units: 2, Strain units: 8). Other amplifier units can be combined for a maximum of 10 unit configuration.

(*2) SSD unit is optional. When the SSD unit is simultaneously used with the High Voltage and Logic/Pulse modules, pulse input channels will become limited.

(*3) Outputs recorded data from the Voltage, Voltage/Temperature, High-speed Voltage, High Voltage, Strain, Accleration units. Temperature, Humidity data is not available for the GL7-DCO module. Sine wave, pulse wave, triangle wave and simple wave form are possible with the DC voltage output module.

 

  Contact a Graphtec Instruments representative to determine the efficacy of our data acquisition devices for your industry.