GL800 |
USED IN AUTOMOTIVE HVAC MONITORING |
|
|
 |
|
| |
|
|
When automotive manufacturing wants to test their HVAC condition in the passenger room—they want to monitor and compare environments of the passenger room and engine room via electrical signal.
The GL800 measures all the parameters by 14 points of the temperature. The GL800 records continuous data of the running motor for 3 days.
The report was created in CSV format to match the company's existing Excel report format. |
|
|
| |
| |
|
Number of analog input terminal units |
1 unit (20 ch) or Extension unit (max 200ch) |
Input Range |
Voltage |
20 mV - 50 V and 1-5V/ f s. |
Thermocouple |
R/S, B, K, E, T, J, N, W, PT |
RTD (Resistance temperature sensor) |
Pt100 and JPt100 |
Humidity |
0 to 100% RH |
Sampling |
100ms - 1/h (100ms when 10-ch max are used) |
Logic input |
|
Pulse input |
|
Trigger input |
|
Alarm output |
4 channel |
Built-in memory |
12 MB |
Screen |
5.75" TFT color LCD |
PC interface |
USB 2.0, Ethernet |
Rated power source |
AC adapter, battery and DC drive |
External size (approximately) |
232 mm × 152 mm × 50 mm |
|
Number of channels |
|
Input method |
Scan method, all channels isolated, Non Balanced input |
Isolation |
|
|
|
|
|
| |
| • |
Built-in Ethernet and USB 2.0 interfaces
|
| • |
Compact 7.6”x4.8” and approx weight of 1lb
|
| • |
Direct recording to USB memory sticks, up to 1GB |
| • |
12MB Built-in Non-volatile memory retains data even after the GL800 is turned off |
| • |
Voltage( 20mV to 50V), Temp Thermo-couplers (K, E, J, T, N, R, S, T, B, W) and Humidity |
| • |
Up to 200 Multi-function PhotoMOS relay isolated input channels |
| • |
Optional battery pack provides up to 9 hours of continuous recording |
| • |
Battery also functions as a UPS in the event of AC power failure |
| • |
16-bit A/D converters (14-bit processing) |
| • |
Max Sample rate of 10 Samples/second |
| • |
Statistical analysis functions |
|
| |
| |
| |
| How to Purchase |
| |
|
| |
| |
|
| |
| |
|
|
|
| |
 |
| |
|
|
|