INSTRUMENTS    >   PRODUCTS  >    COMPACT DATALOGGER GL100 >    GL100-N-DPA-AC50A, AC100A, AC200A

 

 

GL100-N-DPA-AC50A

GL100-N-DPA-AC100A

GL100-N-DPA-AC200A

GL100-N-3AT-1-ECommerce__41220.1504888686.220.290.jpg
 

NON-WIRELESS DATALOGGER WITH CURREN/POWER SENSOR

GL100-N-DPA-AC50A

Data logger with AC current sensor with max 50A current sensor. Used with Support single phase 2-wire, single-phase 3-wire, and 3-phase 3-wire connection. Can Add one additional GS-AC sensor (50A, 100A, or 200A)

GL100-N-DPA-AC100A

Data logger with AC current sensor with max 100A current sensor. Used with steady state voltage AC level. Rated measuring current: 50 A AC (Length of cable to adapter is approx. 200 mm) Rated measuring current: 100 A AC (Length Support single phase 2-wire, single-phase 3-wire, and 3-phase 3-wire connection. Can Add one additional GS-AC sensor (50A, 100A, or 200A)

GL100-N-DPA-AC200A

Data logger with AC current sensor with max 200A current sensor. Used with steady state voltage AC level. Support single phase 2-wire, single-phase 3-wire, and 3-phase 3-wire connection. Reads Power with adjustable power factor. Can Add one additional GS-AC sensor (50A, 100A, or 200A)

Item Description
GS-AC50A Rated measuring current: 50 A AC (Length of cable to adapter is approx. 200 mm)
GS-AC100A Rated measuring current: 100 A AC (Length of cable to adapter is approx. 200 mm)
GS-AC200A Rated measuring current: 200 A AC (Length of cable to adapter is approx. 200 mm)

GL100-WL, GL100-N MAIN UNIT SPECIFICATIONS

Item Description
Number of channels Varies by the input module used, and measurement type is fixed with each input module
Input method, Type of input terminal
Output signal Alarm (1 channel), solid state switch with optical isolation (Optocoupler, Max. load is the 30 V, 50 mA)
Interface to PC USB (micro USB B type connector), Wireless LAN (WLAN) in GL100-WL
Wireless LAN (in GL100-WL) Standards: IEEE802.11b, Communication distance: approx. 40 m
* It varies by the condition of the LAN. Real-time transfer rate is up to 500ms. The WLAN is able to disable. (It is enabled in the factory default setting)
Storage device Built-in memory: RAM (Approx. 4.9 MB)
External memory: microSD memory card
* Maximum file size for captured data is 1.9MB. It is recommended to use the microSD memory card that supports sleep mode. (Example: TS4GUSDHC4, made by Transcend)
Display LCD (backlit monochrome, graphical type 128 x 64 dots)
Contents: Captured data and Setting menu (Stored data is not able to replay. It is able to replay using the PC application software.)
Functions • Real-time data capturing
• Display the captured data value to the LCD in real-time and save the monitoring values
• Set conditions using the Menu setting
While using USB port:
• Output captured data in real-time
• Output the saved data from the internal memory
• Full control of the GL100 from the PC application software
While using Wireless LAN (in GL100-WL):
• Output captured data in real-time
• Output the saved data from the internal memory
• Full control of the GL100 from the PC application software
• Simple control of the GL100 from the application software of Smart Device
• Send warnings via the e-mail
Alarm • Action
Outputs the signal when the measuring data reaches the present conditions of alarm
• Source
Level of measuring data
• Detecting method
Condition: Higher or lower (signal is higher or lower than the threshold)
Combination: OR
Trigger • Action
Start or stop the recording of captured data by trigger
• Source
Start trigger: OFF, Level (*), Alarm, or Date
Stop trigger: OFF, Level (*), Alarm
* Level trigger is available in the analog input of the GS-4VT, GS-4TSR, and GS-3AT module.
• Detecting method of the Level (*)
Condition: Rising or Falling (signal is passed through the threshold)
Combination: OR or AND
Dustproof and waterproof IP54 compatible (*)
* It is effective only in the condition that the input module is set to the GL100 and then the covers of connector and battery are closed. It is recommended to replace the packing of cover in periodically.
Power source • Alkaline battery (AA size x 2)
• USB bus-power (5V, 200 mA) (*)
* When AC adapter for USB device is used, the required power capacity is 5V, 1A. Battery and AC adapter is not included.
Operating environment Temperature: -10 °C to 50 °C
Humidity: up to 80 % RH (non condensed)
External dimension [W x D x H] Approx. 66 x 100 x 27 mm (exclude protrusion)
Weight GL100-N: Approx. 125 g, GL100-WL: Approx. 130
 

INSTRUMENTS    >   PRODUCTS  >    COMPACT DATALOGGER GL100 >    GL100-N-DPA-AC50A, AC100A, AC200A