B-565 WITHSTAND HIGH-VOLT HIGH-PRECISION INPUT |
B-563SL-30 30CH SCREWLESS INPUT TERMINAL |
B-563 20CH SCREW INPUT TERMINAL |
B-563SL 20CH SCREWLESS INPUT TERMINAL |
|||||||
Number of input channels | 20ch | 30ch | 20ch | 20ch | ||||||
Input terminal type | M3 screw-type | Screwless | M3 screw-type | Screwless | ||||||
Input method |
Photo MOS relay scanning system
All channels isolated, balanced input |
|||||||||
Measurement ranges | Voltage | 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100 V, 1-5 V F.S. | ||||||||
Temperature | Thermocouples:K, J, E, T, R, S, B, N, C (W: WRe5-26) | |||||||||
RTD (only 3 wire type is supported) : Pt100, JPt100, Pt1000(IEC751) | (* RTD cannot be connected.) | |||||||||
Temperature range: 100°C, 500°C, 2000°C (In the case of Fahrenheit: 150°F, 750°F, 3000°F) | ||||||||||
Humidity | 0 to 100% (Optional humidity sensor B-530 is required) | |||||||||
Maximum permissible input voltage | Between +/– terminals |
20mV to 2V range (60Vp-p)
5V to 100V range (110Vp-p) |
||||||||
Between input terminal/input terminal | 600Vp-p | 60Vp-p | ||||||||
Between input terminal/GND | 300Vp-p | 60Vp-p | ||||||||
Withstand voltage | Between input terminal/input terminal | 600Vp-p | 350Vp-p 1 minute | |||||||
Between input terminal/GND | 2300VACrms 1 minute | 350Vp-p 1 minute | ||||||||
Voltage measurement accuracy | ±(0.05%ofF.S.+10μV) | ±0.1% of F.S. | ||||||||
Operating environment | 0 to 45℃ | |||||||||
Dimensions(*including GL860) | 240×166×52.5mm (exclude protrusion) | 240×158×52.5mm (exclude protrusion) | ||||||||
Weight(*including GL860) | 1035g (exclude AC adapter & battery) | 1010g(exclude AC adapter & battery) |
B-565
< Between +/– terminals (A) >
– Maximum input voltage: 60Vp-p (Range of 20mV to 2V)
110Vp-p (Range of 5V to 100V)
< Between input terminal/input terminal (B) >
– Maximum input voltage: 600Vp-p
– Withstand voltage: 600Vp-p
< Between input terminal/GND (C) >
– Maximum input voltage: 300Vp-p
– Withstand voltage: 2300Vp-p at 1 minute
B-563SL-30 / B-563 / B-563SL
< Between +/– terminals (A) >
– Maximum input voltage: 60Vp-p (Range of 20mV to 2V)
         110Vp-p (Range of 5V to 100V)
< Between input terminal/input terminal (B) >
– Maximum input voltage: 60Vp-p
– Withstand voltage: 350Vp-p at 1 minute
< Between input terminal/GND (C) >
– Maximum input voltage: 60Vp-p
– Withstand voltage: 350Vp-p at 1 minute
GL860 TERMINALS
4 types of terminals including High Withstand Voltage B-565
are now available for the NEW GL860 Data Logger.
Select the terminal that best suits your measurement application.
OVERVIEW | TERMINALS | G-REMOTE | SOFTWARE | SPECIFICATIONS | ACCESSORIES | DOWNLOAD
B-565
Withstand High Voltage High Precision Input Terminal
B-563SL-30
30 Channel Screwless
Input Terminal
B-563
20 Channel Screw
Input Terminal
B-563SL
20 Channel Screwless
Input Terminal
Channel Expansion of Analog Signal Input Port
The GL860 is expandable up to 200 channels.
The input terminal and GL860 can be extended by using the connection cable for extension terminal (50cm / 2m)
*If the measurement is affected by noise, slow down the sampling interval.